A data set of critical heat flux of boiling R-12 in uniformly heated vertical tubes under transient conditions

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

A critical heat flux (CHF) data set under various transient conditions employing R-12 (Freon 12 or CCl2F2) as the test fluid is provided. Transients were carried out by varying one, two, or three parameters among flow rate, pressure, and thermal power, taking care to investigate all possible combinations. Other parameters were kept constant during the test. Reference steady-state CHF tests were conducted over a wide experimental range, and results are presented here. The employed test section is a stainless steel tube (7.72 mm I.D., 8.52 mm O.D., 2.3 m long) heated by direct passage of a dc current. © 1992.
Original languageEnglish
Pages (from-to)78 - 107
Number of pages30
JournalExperimental Thermal and Fluid Science
Volume5
Issue number1
DOIs
Publication statusPublished - 1992

    Fingerprint

All Science Journal Classification (ASJC) codes

  • Chemical Engineering(all)
  • Nuclear Energy and Engineering
  • Aerospace Engineering
  • Mechanical Engineering
  • Fluid Flow and Transfer Processes

Cite this