Comparison between SPARC E-meter measurements and simulations

C. Ronsivalle, L. Giannessi, M. Quattromini, A. Bacci, A.R. Rossi, L. Serafini, M. Boscolo, E. Chiadroni, M. Ferrario, D. Filippetto, V. Fusco, G. Gatti, M. Migliorati, A. Mostacci, C. Vaccarezza, C. Vicario, A. Cianchi, M. Petrarca

Research output: Contribution to conferencePaper

1 Citation (Scopus)

Abstract

For the SPARC photoinjector commissioning the emittance compensation process has been studied experimentally under different beam conditions (variation of charge, spot size, beam shape....) by a novel device called "emittance-meter", consisting in a movable emittance measurement system based on the 1D pepper pot method scanning a region 1.2 m long downstream the RF-gun. The results of a detailed comparison between the measurements and beam dynamics simulations performed by the codes (PARMELA,HOMDYN,TREDI) employed for SPARC design are presented and discussed here. ©2007 IEEE.
Original languageEnglish
DOIs
Publication statusPublished - 2007
Externally publishedYes
EventIEEE Particle Accelerator Conference, PAC07 - , United States
Duration: 1 Jan 2007 → …

Conference

ConferenceIEEE Particle Accelerator Conference, PAC07
CountryUnited States
Period1/1/07 → …

    Fingerprint

All Science Journal Classification (ASJC) codes

  • Engineering(all)

Cite this

Ronsivalle, C., Giannessi, L., Quattromini, M., Bacci, A., Rossi, A. R., Serafini, L., ... Petrarca, M. (2007). Comparison between SPARC E-meter measurements and simulations. Paper presented at IEEE Particle Accelerator Conference, PAC07, United States. https://doi.org/10.1109/PAC.2007.4440957