Diagnostics of the ITER neutral beam test facility

R. Pasqualotto, G. Serianni, P. Sonato, M. Agostini, M. Brombin, G. Croci, M. Dalla Palma, M. De Muri, E. Gazza, G. Gorini, N. Pomaro, A. Rizzolo, M. Spolaore, B. Zaniol

Research output: Contribution to journalArticle

60 Citations (Scopus)

Abstract

The ITER heating neutral beam (HNB) injector, based on negative ions accelerated at 1 MV, will be tested and optimized in the SPIDER source and MITICA full injector prototypes, using a set of diagnostics not available on the ITER HNB. The RF source, where the H-D-production is enhanced by cesium evaporation, will be monitored with thermocouples, electrostatic probes, optical emission spectroscopy, cavity ring down, and laser absorption spectroscopy. The beam is analyzed by cooling water calorimetry, a short pulse instrumented calorimeter, beam emission spectroscopy, visible tomography, and neutron imaging. Design of the diagnostic systems is presented. © 2012 EURATOM.
Original languageEnglish
Article number02B103
Pages (from-to)-
JournalReview of Scientific Instruments
Volume83
Issue number2
DOIs
Publication statusPublished - 2012
Externally publishedYes

    Fingerprint

All Science Journal Classification (ASJC) codes

  • Instrumentation

Cite this

Pasqualotto, R., Serianni, G., Sonato, P., Agostini, M., Brombin, M., Croci, G., ... Zaniol, B. (2012). Diagnostics of the ITER neutral beam test facility. Review of Scientific Instruments, 83(2), -. [02B103]. https://doi.org/10.1063/1.3662017