Electromagnetic transducers close to high-temperature plasma in the thermonuclear fusion experiment RFX

Pietro Florentin, Simone Peruzzo, Nicola Pomaro

Research output: Contribution to journalArticle

Abstract

RFX is a magnetically confined fusion experiment in operation since 1992 in Padova, Italy. Analysis of the magnetic field is essential for the safe operation of the machine and the understanding of high-temperature plasma dynamics. Both of these issues require an accurate electromagnetic diagnostic system. In this paper, after a discussion of the problems related to magnetic measurements in fusion experiments, with particular reference to the RFX environment, the probes recently installed inside the vacuum vessel will be described.
Original languageEnglish
Pages (from-to)290 - 293
Number of pages4
JournalIEEE Transactions on Instrumentation and Measurement
Volume49
Issue number2
DOIs
Publication statusPublished - 2000
Externally publishedYes

    Fingerprint

All Science Journal Classification (ASJC) codes

  • Electrical and Electronic Engineering
  • Instrumentation

Cite this