Fluctuation measurements with emissive probes in tokamaks

J. Adámek, I. Ďuran, M. Hron, J. Stöckel, P. Balan, R. Schrittwieser, C. Ionita, E. Martines, M. Tichý, G. Van Oost

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

A new probe head, composed of two electro-emissive probes and two Langmuir probes has been designed to measure edge fluctuations in the CASTOR tokamak. In this contribution, only one Langmuir and one electron-emissive probe are used to measure the temperature and potential fluctuations and the phase angle between them.
Original languageEnglish
Pages (from-to)1115 - 1120
Number of pages6
JournalCzechoslovak Journal of Physics
Volume52
Issue number10
DOIs
Publication statusPublished - Oct 2002
Externally publishedYes

    Fingerprint

All Science Journal Classification (ASJC) codes

  • Physics and Astronomy(all)

Cite this

Adámek, J., Ďuran, I., Hron, M., Stöckel, J., Balan, P., Schrittwieser, R., Ionita, C., Martines, E., Tichý, M., & Van Oost, G. (2002). Fluctuation measurements with emissive probes in tokamaks. Czechoslovak Journal of Physics, 52(10), 1115 - 1120. https://doi.org/10.1023/A:1021080123095