Measurement of mass attenuation coefficients for four mixtures using X-rays from 13 keV up to 40 keV

M. Angelone, A. Esposito, M. Chiti, A. Gentile

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

The total absorption coefficients for some selected organic compounds relevant to health physics, Triaflol BN (C3H4O2)n, Triaflol TN (C12H18O7)n, Kapton (C44H20O10)n, and Melinex (C10H8N4O4)nwere measured in the X-ray energy range from 13 keV up to about 40 keV using a collimator, high purity germanium detector with thin Be window and variable energy X-ray source. The measured values are compared with the theoretical ones obtained using the XCOM code. The agreement is generally good within a few percent. © 2001 Elsevier Science Ltd. All rights reserved.
Original languageEnglish
Pages (from-to)547 - 548
Number of pages2
JournalRadiation Physics and Chemistry
Volume61
Issue number3-6
DOIs
Publication statusPublished - 2001
Externally publishedYes

    Fingerprint

All Science Journal Classification (ASJC) codes

  • Radiation

Cite this