The DTT device: Safety, fuelling and auxiliary system

G. Mazzitelli, M.L. Apicella, S. Ciattaglia, A. Colangeli, G. Maddaluno, D. Marocco, R. Martone, R. Villari

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Apparently miscellanea of arguments are discussed in this paper but nevertheless all them are strictly related to safety of the DTT project. DTT should operate integrating all the reactor relevant physics and technology features, e.g. significant power loads, flexible divertors, plasma edge and core conditions approaching those of DEMO. The licensing process is discussed in the framework of the Italian law for which DTT will be classified as a radiogenic machine of category A. The guidelines for neutronics, fueling and pumping issues are highlighted. Finally, the cooling systems and the cryostat project are also illustrated.
Original languageEnglish
Pages (from-to)375 - 381
Number of pages7
JournalFusion Engineering and Design
Volume122
DOIs
Publication statusPublished - 1 Nov 2017
Externally publishedYes

    Fingerprint

All Science Journal Classification (ASJC) codes

  • Civil and Structural Engineering
  • Nuclear Energy and Engineering
  • Materials Science(all)
  • Mechanical Engineering

Cite this

Mazzitelli, G., Apicella, M. L., Ciattaglia, S., Colangeli, A., Maddaluno, G., Marocco, D., Martone, R., & Villari, R. (2017). The DTT device: Safety, fuelling and auxiliary system. Fusion Engineering and Design, 122, 375 - 381. https://doi.org/10.1016/j.fusengdes.2017.05.131